Rosemount / Emerson 罗斯蒙特 T56 水质检测仪器

分享
  • 后询价或查看价格

  • T56

  • 水质检测仪器

  • Rosemount / Emerson 罗斯蒙特

  • 请咨询供应商

  • Rosemount / Emerson 罗斯蒙特

联系销售
专家支持

特性

  • COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly
  • CHOOSE U.S. EPA METHOD 180.1 or ISO METHOD 7027 compliant sensors
  • RANGE 0-200 NTU
  • RESOLUTION 0.001 NTU
  • EASY TO USE 56 FOUR-WIRE ANALYZER with four analog outputs and four programmable alarm relays
  • INTUITIVE, USER-FRIENDLY MENU in nine languages makes setup and calibration easy
  • HART® DIGITAL COMMUNICATIONS – standard
  • DATA LOGGER – stores thirty days of process data and diagnostics for on-screen viewing or download via a USB 2.0 data port

"The T56 Clarity II™ turbidimeter system is intended for the determination of turbidity in water. Low stray light, high stability, efficient bubble rejection, and a display resolution of 0.001 NTU make Clarity II™ ideal for monitoring the turbidity of filtered drinking water.","The T56 Clarity II™ is a complete system. It includes a single or dual input analyzer, sensor(s), debubbler\/flow cell(s), and a cable for each sensor. The system complies with ISO method 7027 when used with the ISO\/LED sensor and with EPA method 180.1 when used with the EPA\/incandescent sensor. T56 Clarity II uses a two-stage debubbler that reduces bubble accumulation in the measured water sample to prevent erroneous turbidity readings.","The T56 Clarity II™ turbidimeter incorporates the model 56 advanced four-wire analyzer with a full color display screen. The 56 instrument is easy-to-read and offers a modular design with slide-in measurement boards, extensive diagnostics and a complete on-screen instruction manual and troubleshooting guide. A large capacity data logger, an event logger\/audit trail, a USB data transfer port and HART communications are offered with every unit.","Clarity II is a trademark of Emerson Process Management."

T56 水质检测仪器技术参数

点击查看 0 个替代产品
规格项 参数值 勾选搜索替代
特 性
控制继电器数量 4 #
电 气
电气输出 Analog Current; Switch / Alarm Relay
连 接 & 显 示
显示类型 Video
用户控件 Digital Front Panel
环 境
工作温度 32 to 131 F (0 to 55 C)
物 理
外观形式 Lab / Benchtop
更多规格
精度 2 ±% Full Scale
特性和功能 Self-test / Diagnostics
最大输入通道 1 to 2 (# channels)
介质温度 40 to 95 F (4 to 35 C)
产品类别 Water Quality Testing Instruments
浊度范围 0.0 to 200 NTU (Nephelometric Turbidity Units)
水质参数 Water Quality Measurement Instrument; Turbidity

产品替代

找到 个替代产品

资料下载

T56 水质检测仪器资源附件
文件名称 大小 操作
product-data-t56-clarity-ii-turbidimeter-en-71658 1.30 MB

环境传感器交流圈

约4圈友等你加入

    加载中···

    专家支持

    0 / 300

    选择图片

    确定提交

    提交成功

    系统自动将您的问题推送给专家解答

    查看专家解答
    请扫码进入传感圈小程序

    如何查看专家解答您的问题?

    1
    2
    3
    4