The Andros 6511 offers unparalleled accuracy and performance. Now taking advantage of the latest technology, Andros brings you a product with superior performance and reliability.","The Non-Dispersive InfraRed (NDIR) sensor can measure the greenhouse gases CO2 and Methane via RS-232 communications with the host.","Every Andros 6511 NDIR bench is individually calibrated for operation from 0° C to 50° C over the entire range of specified concentrations.","The results of this intensive calibration process are stored within each system providing the most accurate analysis possible. This attention to detail provides a highly accurate factory calibration of the NDIR analyzer. Andros is so confident in our factory calibration that our customers need never calibrate the NDIR analyzer again.","The Andros 6511 is designed to meet and exceed performance requirements for portable or fixed leak detectors of toxics or combustibles.","The enhanced optics and electronics of the 6511 has virtually eliminated zero drift after the initial warm up period.","Prior to this breakthrough, frequent zeroing of an analyzer was often required during the first half-hour of operation for the most sensitive measurements. Now, with just two zeroes during the first three minutes, the new Andros 6511 is ready to meet all accuracy specifications.","The Andros 6511 optics incorporates precision beam collimating architecture.","A concentrated infrared beam generated from a proprietary emitter, passes through a precision lens into a cleanable or replaceable gold-lined sample cell that the gas of interest is flowing through.","The beam then passes into an optical assembly of highly specialized filters and a unique multi-element detector.","The 6511 embedded Operating System (OS) software has been developed to provide our customers the means to tailor a number of operations in the 6511 without the need for a custom OS. All calculations are performed in real time for transmission to your host system.
特性
- 4气体容量
- rs232输出
- 流量监测压差
- 低功率
- 快速响应时间
ANDROS 6511 气体仪器技术参数
规格项 | 参数值 | 勾选搜索替代 |
特 性 | ||
响应时间 | 40 seconds | |
环 境 | ||
工作温度 | 32 to 158 F (0 to 70 C) | |
工作湿度 | 95 % | |
物 理 | ||
安装类型 | Fixed | |
更多技术信息 | ||
测量类型 | %Volume; Trace | |
气体类型 | Toxic; Combustible; CO2 (0.00 to 16.00%); CO (0.000 to 15.000%); Hydrocarbons (40% to 100%); H2S; Methane (CH4) / Natural Gas (40% to 100%); NO; NO2; O2 (1.01 to 25.00%); SO2 | |
仪表类型 | Monitor | |
应用 | Process Gas | |
更多规格 | ||
传感技术 | Electrochemical; Infrared | |
Number of Gases Monitored | Multi | |
产品类别 | Gas Instruments |
产品替代
声明:本产品内容及配图源自互联网收集或平台用户自行上传,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容真实性,不承担此类作品侵权行为的直接责任及连带责任。如涉及作品内容、版权等问题,请联系本网处理,侵权内容将在一周内下架整改。
气体仪器相关品牌
气体仪器同类产品
加载中···