MHSA 系列 MAP传感器/汽车绝对压力传感器
-
登录 后询价或查看价格
-
MHSA 系列
-
SIMST 上海芯敏微系统
-
请咨询供应商
-
SIMST 上海芯敏微系统
产品介绍
MHSA series pressure sensor module is consists of absolute pressure sensor, signal conditioning circuit and additional electronic components. The pressure sensor systems mounted on FR4 PCB. This temperature compensated and calibrated sensor provides an accurate, high level analog output signal that is proportional to applied pressure. The maximum pressure rang of the sensor cell is 0~4000 KPa absolute pressure. The supply voltage is 5±0.5V,the type supply current is 2.5mA. The pressure sensor module has the features of the small form factor and high reliability. Application fields include automotive pressure monitoring, pneumatic gages, hand-held meters, industrial controls and so on.
Operating Characteristics
Table 1. Operating Characteristics (VS = 5.0 Vdc, TA = 25°C.
Notes:
1. Device is ratiometric within this specified excitation range.
2. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the minimum rated pressure.
3. Accuracy is the deviation in actual output from nominal output over the entire pressure range and temperature range as a percent of span at 25°C due to all sources of error including the following:
Linearity:Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C.
4. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a specified step change in pressure.
5. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
6. Offset Stability is the product's output deviation when subjected to 1000 hours of P