"Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 3 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 2 x cable entries tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSTRLock Style = HingeNormal State Configuration = 3NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 2Size of Cable Entries = M16 x 1.5Conduit Entry = M16"
"Hinge switch for right-side mounting. Pivot angle 0° â†' 270°. Freely adjustable switch point. Integrated fine adjustment system makes readjusting easy even after the switch point has been set. Switch point can be reset with a change kit. Wired or plugged connection. Axial or radial connection directionSeries = SHS3Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M12 Plug ConnectorConduit Entry = M12Shaft Length = 63mm"
"Hinge switch for right-side mounting. Pivot angle 0° â†' 270°. Freely adjustable switch point. Integrated fine adjustment system makes readjusting easy even after the switch point has been set. Switch point can be reset with a change kit. Wired or plugged connection. Axial or radial connection directionSeries = SHS3Lock Style = HingeNormal State Configuration = 2NC, NOMaximum Current = 5 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M6 x 4Conduit Entry = M6Shaft Length = 63mm"
"Insulation encapsulated. Operation via axis of rotation. For mounting on hinge axes. For monitoring rotatable and pivotable safety equipment. Switch casing in accordance with EN 50047. Protection rating IP 65Series = I88Normal State Configuration = 2NCMaximum Current = 5 AMaximum AC Voltage = 240VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M3Trigger Angle Range = ±3.5°Minimum Operating Temperature = -30°CMaximum Operating Temperature = +80°C"
"These switches are designed for hinged guards and have a built-in actuator lever which operates the contact block with a positive mechanical linkage. N\/C safety contact positively disconnected after just 4.5° rotation. Head can be turned in any one of four 90° positions. Slow action contact system. The housing with snap-on cover fastened without screws to facilitate easy connectionSeries = TC 236Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M20Shaft Length = 70mm"
"These switches are designed for hinged guards and have a built-in actuator lever which operates the contact block with a positive mechanical linkage. N\/C safety contact positively disconnected after just 4.5° rotation. Head can be turned in any one of four 90° positions. Slow action contact system. The housing with snap-on cover fastened without screws to facilitate easy connectionSeries = TC 236Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M20Shaft Length = 70mm"
"These switches are designed for hinged guards and have a built-in actuator lever which operates the contact block with a positive mechanical linkage. N\/C safety contact positively disconnected after just 4.5° rotation. Head can be turned in any one of four 90° positions. Slow action contact system. The housing with snap-on cover fastened without screws to facilitate easy connectionSeries = TC 236Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M20Shaft Length = 70mm"
"This precision switch is designed for use on hinged guards, with the operating shaft fixed to the hinge bolt. On opening the guard, the shaft will rotate, breaking the N\/C contacts with a positive mechanical linkage. The stainless steel shaft has a 10mm bore hole. Positive break is achieved with just 2 degrees of rotationSeries = TVS 335Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M20Shaft Length = 24mm"
"This precision switch is designed for use on hinged guards, with the operating shaft fixed to the hinge bolt. On opening the guard, the shaft will rotate, breaking the N\/C contacts with a positive mechanical linkage. The stainless steel shaft has a 10mm bore hole. Positive break is achieved with just 2 degrees of rotationSeries = TVS 335Lock Style = HingeNormal State Configuration = 2NCMaximum Current = 4 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 1Size of Cable Entries = M20 x 1.5Conduit Entry = M20Shaft Length = 24mm"
"The SIRIUS 3SE5 Series hinge switch is designed for monitoring hinged doors and flaps. These mechanical position switches offer excellent protection from tampering thanks to the fixed, positive pivoting point connection between switch and door hinge. They have a standard enclosure according to EN 50047 and EN 50041 and a very small operating angle. Simultaneous shut down and signalling is provided in addition by the snap-action contacts.For the mechanical monitoring of protective doors or flaps. Protection up to Cat 4 (EN 954-1), Up to SIL 3 IEC 62061. Snap on contacts. Simple, fast wiring offers approx 20 to 25% reduction in connection time. Cable entry M20 x 1.5. Actuator head can be rotated in 22.5° incrementsRange = SIRIUSSeries = 3SE5Lock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 1 A dc, 4.2 A acMaximum AC Voltage = 240VMaximum DC Voltage = 24VNumber of Cable Entries = 2Size of Cable Entries = M20 x 1.5Conduit Entry = M20"
"Introducing the XCS PL range of Safety Switches. As far as safety is involved all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses and the automotive sector. Increase productivity thanks to the third contact dedicated to diagnostics.Head can be oriented in 4 directions. Dimensions: H 60 x W 30 x D 30mm. Operating Temperature -25 to 70°CRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"Actuator lever on the right or on the left. Head can be oriented in 4 directionsRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = 2NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 2Size of Cable Entries = M16 x 11Conduit Entry = M16"
"Introducing the XCS PL range of Safety Switches. As far as safety is involved all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses and the automotive sector. Increase productivity thanks to the third contact dedicated to diagnostics.Head can be oriented in 4 directions. Dimensions: H 60 x W 30 x D 30mm. Operating Temperature -25 to 70°CRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"Introducing the XCS PL range of Safety Switches. As far as safety is involved all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses and the automotive sector. Increase productivity thanks to the third contact dedicated to diagnostics.Head can be oriented in 4 directions. Dimensions: H 60 x W 30 x D 30mm. Operating Temperature -25 to 70°CRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"The Rotacam is heavy-duty, hinge-actuated safety-interlock switch. It can be used as, or connected to, the existing hinge pin for direct operation of the switch. Machine power is isolated when the guard has been opened just 5°. For applications requiring a larger degree of operation, the internal cam can be adjusted from 5…11°.Can be used as a hinge pin on light and medium weight guard doors. Isolates power within 5° of door movement (2° to operate 2N\/C safety contacts, 3° to operate 1N\/O auxiliary - which can be used to indicate which guard has been opened, or can operate an alarm). Degree of operation can be customized with adjustable cam. Robust die-cast case, ideal for heavy-duty applications. Contacts 2 NC & 1 NO. Forced guided contacts - complies with EN 1088, IEC 947-5-1Range = RotacamSeries = 440HLock Style = HingeNormal State Configuration = NO\/2NCSize of Cable Entries = M16Conduit Entry = M16Shaft Length = 30mm"
"Intended for applications where it is impractical or inconvenient to fit a key switch to a door. Hinge slider switch is fitted to the fixed part of the machine with slider mechanism (usually) in top of the door. Detects when the door has been opened, thus the N\/C contacts are opened. Design ensures no weight, torques or strains are acting directly on the switch. IP66 RatingSeries = GSSNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 600VMaximum DC Voltage = 250VConduit Entry = PG13.5Shaft Length = 70mmMinimum Operating Temperature = -25°CMaximum Operating Temperature = +85°C"
"Intended for applications where it is impractical or inconvenient to fit a key switch to a door. Hinge slider switch is fitted to the fixed part of the machine with slider mechanism (usually) in top of the door. Detects when the door has been opened, thus the N\/C contacts are opened. Design ensures no weight, torques or strains are acting directly on the switch. IP66 RatingSeries = GSSNormal State Configuration = 2NCMaximum Current = 6 AMaximum AC Voltage = 600VMaximum DC Voltage = 250VConduit Entry = PG13.5Shaft Length = 70mmMinimum Operating Temperature = -25°CMaximum Operating Temperature = +85°C"
"Intended for applications where it is impractical or inconvenient to fit a key switch to a door. Hinge slider switch is fitted to the fixed part of the machine with slider mechanism (usually) in top of the door. Detects when the door has been opened, thus the N\/C contacts are opened. Design ensures no weight, torques or strains are acting directly on the switch. IP66 RatingSeries = GSSNormal State Configuration = 2NCMaximum Current = 6 AMaximum AC Voltage = 600VMaximum DC Voltage = 250VConduit Entry = PG13.5Shaft Length = 70mmMinimum Operating Temperature = -25°CMaximum Operating Temperature = +85°C"
"Introducing the XCS PL series.Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 2 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 1 x cable entry tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"Introducing the XCS PL series.Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 2 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 1 x cable entry tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = 2NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"Introducing the XCS PL series.Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 2 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 1 x cable entry tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = PG11Conduit Entry = PG11"
"Introducing the XCS PL series.Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 2 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 1 x cable entry tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = 2NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 1Size of Cable Entries = M16 x 1.5Conduit Entry = M16"
"Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 3 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 2 x cable entries tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/2NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 2Size of Cable Entries = M16 x 11Conduit Entry = M16"
"Ideal for light industrial machines fitted with hinged or rotary protective covers with small opening radius e.g. double gate guards. 3 outputs. 5° displaced tripping angle. 4 position turret head. Ingress protection, IP67. Slow break safety contacts with positive opening operations (positive actuation) N\/C contacts open when spindle displaced more than 5°. 2 x cable entries tapped for 11mm cable gland, ISO M16 x 1.5 or ½ NPTRange = PreventaSeries = XCSLock Style = HingeNormal State Configuration = NO\/2NCMaximum Current = 6 AMaximum AC Voltage = 240VMaximum DC Voltage = 250VNumber of Cable Entries = 2Size of Cable Entries = M16 x 11Conduit Entry = M16"
"Thermoplastic enclosure. Double-insulated. Good resistance to oil and petroleum spirit. 111.5 x 92 x 36 mm. 2 cable entries M 20 x 1.5. Simple fitting, especially on 40 mm profilesSeries = TVS 400Lock Style = HingeNormal State Configuration = NO\/2NCMaximum Current = 2 AMaximum AC Voltage = 230VMaximum DC Voltage = 24VNumber of Cable Entries = 2Size of Cable Entries = M20 x 1.5Conduit Entry = M20Trigger Angle Range = 4°"